INVERTER 1 KW PURESINEWAVE 3 YEARS WARRANTY
Specifications
1000w-6000w pure sinewave inverter
1.high frequency
2.full protection inbuilt
3.Green function for power saving
1000w-6000w pure sinewave 120vac ups/inverter
Outstanding Features
1.Micro-processor controlled, automatic.
2.Big charging current with P.F.C charger and fast charging mode.
3.Pure sinewave output suitable for most applications.
4.Green function for power saving.
5.Big surge rating can support Air Conditioning system.
6.Full protection inbuilt.
7.Selectable battery type.
8.Desulphation function provided to extend the battery life.
9.Support ambient temperature up to 50 degree C.
10.Support inductive motor load.
Technical Specification
Input wave form |
Sine wave(Utility or Generator) |
||||||
Nominal voltage |
120VAC |
230VAC |
|||||
Low voltage trip |
90V +/- 4% |
184V/154V +/- 4% |
|||||
Low voltage re engage |
100V +/- 4% |
194V/164V +/- 4% |
|||||
High voltage trip |
140V +/- 4% |
253V +/- 4% |
|||||
High voltage re engage |
135V +/- 4% |
243V +/- 4% |
|||||
Max input AC voltage |
150VAC |
270VAC |
|||||
Nominal input frequency |
50Hz or 60Hz (Auto detect) |
||||||
Low freq trip |
47Hz for 50Hz, 57Hz for 60Hz |
||||||
High freq trip |
55Hz for 50Hz, 65Hz for 60Hz |
||||||
Output wave form |
(Bypass mode) same as input |
||||||
Overload protection |
Circuit breaker |
||||||
Short circuit protection |
Circuit breaker |
||||||
Transfer switch rating |
30amp or 40amp |
||||||
Efficiency on line transfer mode |
95% + |
||||||
Line transfer time |
10ms Typical |
||||||
Bypass without battery connected |
Yes |
||||||
Max bypass current |
30 amp or 40 amp |
||||||
Bypass over load current |
35 amp or 45 amp : Alarm |
||||||
Inverter specification/output |
|||||||
Output wave form |
Pure sine wave or quasi sine wave |
||||||
Output continuos power watts |
1000 |
2000 |
3000 |
4000 |
5000 |
6000 |
|
Output continuos power VA |
1000 |
2000 |
3000 |
4000 |
5000 |
6000 |
|
Power factor |
0.9-1.0 |
||||||
Nominal output voltage rms |
120/230 VAC |
||||||
Output voltage regulation |
10% rms |
||||||
Output frequency |
50Hz +/- 0.3Hz or 60Hz +/- 0.3Hz |
||||||
Norminal efficiency |
>88% |
||||||
Surge ratings |
3000 |
6000 |
9000 |
12000 |
15000 |
18000 |
|
Short circuit protection |
Yes, fault after 10 secs |
||||||
Inverter specification/input |
|||||||
Nominal input voltage |
12v |
24v |
48v |
||||
Minimum start voltage |
10v |
20v |
40v |
||||
Low battery alarm |
10.5v |
21v |
42v |
||||
Low battery trip |
10v |
20v |
40v |
||||
High voltage alarm |
16v |
32v |
64v |
||||
Power saver |
Below 25 watts when enabled |
||||||
Power saver |
Same switched on/off on remote |
||||||
Charger mode specification |
|||||||
Input voltage range |
95-127 VAC |
194-243 VAC/ 164-243 VAC (W) |
|||||
Output voltage |
Dependent on battery type |
||||||
Charge current |
35A/70A |
||||||
Battery initial voltage for start up |
0-15.7v for 12v (*2 for 24v; *4 for 48v) |
||||||
Over charge protection shutdown |
15.7v for 12v (*2 for 24v; *4 for 48v) |
||||||
Charger curves (4 stage constant current) |
|||||||
4 step digital controlled progressive charge |
|||||||
Battery type |
Fast V |
Float V (*2 for 24v; *4 for 48v) |
|||||
Gel U.S.A |
14.0 |
13.7 |
|||||
A.G.M.1 |
14.1 |
13.4 |
|||||
A.G.M.2 |
14.6 |
13.7 |
|||||
Sealed lead acid |
14.4 |
13.6 |
|||||
Gel euro |
14.4 |
13.8 |
|||||
Open lead acid |
14.8 |
13.3 |
|||||
Calcium |
15.1 |
13.6 |
|||||
De-sulphation |
15.5 for 4hrs |
||||||
Remote control/RS 232/ USB |
Yes. Optional |
||||||
Size(in mm) |
1000/2000/3000 Model:442*218*179mm |
||||||
4000/5000/6000 Model:598*218*179mm |
|||||||
Weight |
1000 |
2000 |
3000 |
4000 |
5000 |
6000 |
|
18kg |
20kg |
22kg |
35kg |
38kg |
40kg |