Model indication method
Model | Part Number |
---|---|
EGM-50TH-10S-2C-D | 101513 |
EGM-50TH-10S-3P-D | 101523 |
EGM-50TH-10S-4C-D | 101508 |
EGM-50TH-10S-7C-D | 101503 |
EGM-50TH-10S-7C-LD | 101501 |
EGM-50TH-10S-7C-LFBD | 101500 |
EGM-50TH-10S-8P-D | 101518 |
Repair parts set
Pumping unit (10MPa, 10ml / min) Relief unit dedicated tool
Model | Part Number |
---|---|
50THPRS-10 | 539461 |
Specifications
Power | DC24V |
Power Consumption | 36W |
Discharge Pressure | 10MPa |
Driving time | Continuous Energization |
Stop time | No Restriction |
Connection Method | DIN terminal |
Guaranteed Grease | Lube Original Grease |
Feed switch | Yes (optional) |
Grease level switch | Yes (7C only) |
Covers | Flame retardant resin(UL94-V0) |
IP standard | Get |
CE standard | Get |
Pump air removal | Driving timeNo Restriction |
Use Consistency Range | NLGI NO. 00. 0. 1 |
Weight | 7C 2.2kg、4C 2.1kg 2C 2.1kg、8P 3.3kg 3P 2.2kg |
Directions for use
● Use manufacturer's warranty grease.
● Never use molybdenum disulfide grease.
● Use lithium grease. (If it is other than Lube original grease, please be sure to consult.)
● Be careful not to mix any foreign matter when replenishing grease or replacing cartridges.
● Be careful not to let air enter the pump when replacing the cartridge.
● After greasing or after replacing the cartridge, be sure to open the air vent plug and vent the air inside the pump.
Wiring digram
Repair parts set