Model indication method
Model | Discharge Port | Part Number |
---|---|---|
BT-102(8) | 8 port | 101111 |
BT-102(4) | 4 port | 101112 |
Specifications
Power | LUBE original 4 AA batteries: Alkaline |
ContinuousDriving time | 5 minutes (6 hours cumulative) |
Interval time | 1–24 hours, 1–31 days(Switched by setting switch) |
Discharge Pressure | 2.5MPa or more |
Pump discharge amount | 1.5mℓ/min |
Pump life time | 100 hours |
Used lubricant | CBT-SU03(Code No: 249150) |
Cartridge Capacity | 200mℓ |
Weight | 1.6kg |
LED lamp display content
During operation | Lighting |
During interval | Extinction |
Cartridge replacement | Lamp flashes once at a time (5 seconds intermittent) |
Battery replacement | LED lamp flashes 2 times in a row(5 seconds intermittent) |
Abnormal setting | LED lamp flashes 3 times in a row(5 seconds intermittent) |
Abnormal boost | LED lamp flashes 4 times in a row(5 seconds intermittent) |
Continuous operation mode (21 times) Filling mode (3 of SW1)*1 |
(LED lamp flashes once at a time (1 second intermittent)) |
※1 Includes cartridge and dry cell
Unit usage conditions
Oil supply piping (nylon pipe): Within 2 m (use the nylon pipe included)
Valve discharge amount and number of points: MU valve (0.1 ml, 1 to 8 places)
■ Pump mounting bolt, nut Hexagon socket head cap screw Size M6-16 × 3
■ Plug MU-BP (Part Number 619840) x 7 pieces
■ One-touch fittings KBE4-01-F ∅ 4 × R 1/8 (Part Number 209523) × 8 pieces
■ Nylon pipe ∅ 4 × 2 m CBT-SU03 (filled) (Part Number 106 834) × 8
■ 4 AA batteries (Part Number 531300)
Dimensional Drawing
Operating EnvIronment Conditions
Use this Pump in the following envIronment.
Ambient temperature: 5 to 45 ° C (indoor use)
Humidity: 35 to 85% RH (no condensation)
Vibration: 9 G or less
(※ Battery life will be extremely shortened if used below 5 ° C.)
* When using cartridge Target Pump, please also target battery.