Honeywell Bullet Camera 2.0MP Network IR 60m. Len 2.7-12mm. MFZ WDR
Honeywell Dome Camera 4.0MP Network IR 30m. Len 2.7-12mm. MFZ WDR
Honeywell Dome Camera 2.0MP Network IR 30m. Len 2.7-12mm. MFZ WDR
Honeywell Eyeball Camera 4.0MP Network IR 60m. Len 2.7-12mm. MFZ WDR Black
Honeywell Eyeball Camera 2.0MP Network IR 60m. Len 2.7-12mm. MFZ WDR Black
Honeywell Eyeball Camera 4.0MP Network IR 40m. Len 2.8mm. WDR Black
Honeywell Eyeball Camera 2.0MP Network IR 40m. Len 3.6mm. WDR Black
Honeywell Eyeball Camera 4.0MP Network IR 40m. Len 2.8mm. WDR White
Honeywell Eyeball Camera 2.0MP Network IR 40m. Len 3.6mm. WDR White
Honeywell Bullet Camera 4.0MP Network IR 40m. Len 3.6mm. WDR
Honeywell Bullet Camera 2.0MP Network IR 40m. Len 3.6mm. WDR
Honeywell Dome Camera 4.0MP Network IR 20m. Len 2.8mm. WDR
Honeywell Micro Dome 4.0MP Network IR 20m. Len 2.8mm. WDR Built-in mic
Honeywell Micro Dome 2.0MP Network IR 20m. Len 2.8mm. WDR Built-in mic
Honeywell DVR 16CH CVBS/AHD 2 SATA 2.0MP
Honeywell DVR 8CH CVBS/AHD 1 SATA 2.0MP
Honeywell DVR 4CH CVBS/AHD 1 SATA 2.0MP
Honeywell Bullet Camera 2.0MP CVBS/CVI/TVI/AHD IR 40m. Len 2.8-12mm.
Honeywell Eyeball Camera 2.0MP CVBS/CVI/TVI/AHD IR 30m. Len 2.8-12mm.
Honeywell Bullet Camera 2.0MP CVBS/CVI/TVI/AHD IR 20m. Len 3.6mm.
Honeywell Eyeball Camera 2.0MP CVBS/CVI/TVI/AHD IR 20m. Len 3.6mm.
FDM-1 is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addres
FZM-1 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit.
FMM-101 is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D) used to supervise a Class B (Style B) circuit of dry-contact input devices.
FRM-1 Addressable Relay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, dampers, control equipment, etc.
FZM-1 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit.
The FRM-1 Relay Control Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built-in rotary switches.
The NOTIFIER ISO-X Fault Isolator Module is used with the NFS-3030, AM2020, AFP1010, NFS-640, AFP-400, AFP-300, AFP-200, AFP-100 and System 5000 (equipped with an AIM-200 module) to protect the system
FMM-1 is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices.
FCM-1 Addressable Control Module provides Notifier intelligent control panels a circuit for Notification Appliances (horns, strobes, speakers) or to monitor a telephone circuit.
Notifier 851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors.
The FSM500K provides both signaling of an alarm to the Fire Indicator Panel and local LED indication of activation.
Notifier FST-851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors.
Notifier 851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors.
The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise.
The 5151 thermal detector meets the needs for applications where rapid response is vital and rapid temperature increases would only be caused by a fire emergency.
System Sensor’s 5600 Series mechanical heat detectors offer a low-cost option for property protection against fire and for non-life-safety installations, where smoke detectors are inappropriate.
System Sensor’s 800 series detectors are 2-wire conventional profile plug-in detectors aimed to meet the performance criteria designated by UL.
The SD-651 is designed to meet the performance criteria designated by UL. Its sensing chambers are sealed against back pressure air flow, dirt, and insects.
The System Sensor BEAM1224S is transmitter / receiver unit and a reflector as fourwire conventional projected beam smoke detectors.